No, shock and chlorine are not the same. I have a Zodiac LM2-24 salt cell that just quit working, none of the lights display. Salt test strip says 3200ppm. Push the RESET button which is located on the main board, and the pump will be reset to factory default settings. AquaPure Salt Water Pool System Downloads Document ID SL6605 Description AquaPure System Brochure File Size 2.01 MB | File Type PDF Document ID H0325600 Description AquaPure Electronic Salt Water Chlorinator & PureLink Water Purification System Power Center & Cell Kit Installation & Operation Manual File Size 3.82 MB | File Type PDF My 6 month old Jandy TruClear Saltwater system recently started showing a Check Cell message and will not chlorinate. 1. Heres a technical guide on the Ei salt system from Zodiac: My EI Series Zodiac Salt chlorinator is leaking through the bottom. As dirt, dust, and other particles build up over time, it can cause the metal probe to become clogged or blocked. Do Not use Rock salt (insoluble impurities mixed with the rock salt can shorten the life of the unit). Make sure all are on and reset the breaker if necessary. You are using an out of date browser. Turn on the chlorinator or increase the chlorine production percentage. Since you say its leaking out of the bottom, its likely the smaller o-rings, probably deteriorated from the chlorine. Step 3: When the instant salt level is stable (and the negative sign still present), cycle slide switch to 'Super Chlorinate' and back to 'Auto'. Thoughts? Dirty pump baskets or clogged impellers or filters can reduce water flow to such a low point that little chlorine is produced. It kills off bacteria and algae, while also serving to clarify and bring the pH levels of a pool back to a normal level when they become unbalanced. Low salt levels can prevent the cell from producing chlorine. Salt level is 3000, so I know it isn't low salt. Check that your flow rate is optimum first, and if so, look into the owners manual for any sort of flow sensor adjustments or maintenance needed. Unfortunately, as with any part of a swimming pool, salt cells can experience malfunctions and eventually stop working. If not, perhaps it could be spot weld repaired, by a knowledgeable welder (? Can I replace to flow terminal in the chlorinated and pool is always cloudy or is it time to replace the chlorinated. Its important to diagnose and replace any faulty electrical components in order to prevent more serious issues with the salt cell. I cant figure out how to make the switch. Your IP: Electronic salt water chlorinator and water purification system power center and cell kit. If I adjust it again down 300ppm more does that now mean I've offset it 900ppm total? Hi Tamara, If a plate snaps off, this could be the end of the cell, since each plate is electrically charged. The coatings tend to wear off the metal plates over time, which can lead to corrosion and failure of the plates. I watched the main screen as it went through its normal routine, but it never tells me what the problem is. Follow the pool surface manufacturers guidelines for your particular pool. Not making any chlorine. BACKUP BATTERY 877-976-5299 or support@solaxx.com, I have an aqua trol salt cell system. After an initial dosage, an annual booster dose is needed to make up for backwash water, or splashout, or rain. Finally, could be contamination of phosphates/nitrates, consuming the chlorine as fast as it is added you can test for phosphates, and treat with a remover, if you havent already. Is there any need to purchase new housing also (complete unit), or should I take the cheaper option of just replacing the internal cell. 178.77.76.15 First, check your flow rate and ensure it is consistent and appropriate for the salt cell you are using. Salt Chlorinator Problems Repair or Replace? You can extend sand filter life by using a Sand Filter Cleaner once or twice per season. Jandy AquaPure Installation And Operation Manual If so, then check the sensor wires and connections. PDF ProLogic/AquaLogic I have a Jandy Aquapure chlorine generating system. 5. What is the symbol behind the Rolex watch in Hawkeye. This can be done by increasing the voltage being sent to the cell or by opening the chlorine production valve.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[336,280],'remodelormove_com-large-leaderboard-2','ezslot_6',158,'0','0'])};__ez_fad_position('div-gpt-ad-remodelormove_com-large-leaderboard-2-0'); Lastly, check the salt level in your water. I have checked my cells and they are clean, the Nano is not giving any errors or codes. Then, you will need to obtain an agent specifically designed to increase salt content, such as Jandys Pro Series Salt Solution. Usual symptoms are low chlorine output, as determined by your water tests, indicator lights or error codes flashing on the control box, or no lights at all. Hi Davy, I have an aqua plus system, have replace the turbo cell a couple of year ago but late last year and right now it is telling my that I have low salt levels. After 24 hours, verify correct salt reading. How do you fix a Jandy salt cell? - Remodel or Move Flow is fine, salt is fine, filters are clean. Output is OFF. My husband is pretty handy at fixing things so if its just a fuse what would he need to look for? Check the water flow. Jandy AquaPure PureLink 3-Port Salt Cell Kit | PLC1400 How do I Reset a Jandy AquaLink System? | ehow If the GFCI fails to . First I would check that the cables and ribbons are all tightly connected. The display on the unit is showing as 3.9gpl and app shows the same 3900 PPM. The sensor is only about a year and a half old. Low salt message popping up, low salt light on and blue power light flashing on and off. If youre uncertain whether your salt cell needs replacing, its best to install a replacement to avoid further damage to your pool. Called to verify stock before purchase and the staff was courteous and knowledgeable. This is why changing this parameter is reserved for the pool professional. Customer Support: We're Here For You | Jandy After the click, quickly push the Diagnostics button 5 times. Once you have this, you will need to add it directly to the chlorinator and turn the adjustment dial to the appropriate setting. 4. Some type of epoxy? If not, it seems that the new Fusion system will not work with the (now discontinued) Duoclear controller, although Im not 100% sure on that either, but cant find anything that says it is. The no flow is on so I was thinking about replacing the yellow cap. Generally, the ideal range for a salt cell setting is between 2 and 10 percent. I have a zodiac tri large chlorination that is 9yrs old. Jandy TruClear 'Check Cell' message | Trouble Free Pool That can be numerous things with water chemistry. How To Troubleshoot Problems with Your Salt Cell - Royal Swimming Pools If your salt system is hardwired, variations in voltage could cause the controller to go a little haywire. The salt cell is fairly new with build up. How can I fix it? would like to hear about, Im sure theyd be especially helpful in this case, I would think, Hi we recently bought a house with a chlorine pool. The new TruClear is an extremely reliable saltwater chlorinator designed for easy installation, use and service. Need to replace electrode. From https://www.justanswer.com/ythiJustAnswer Customer from Los Angeles, CA: How do you calibrate a Jandy aquapure.JustAnswer Customer from Los Angeles, CA:. Rely on its sturdy design and simple features to create your saltwater oasis. This limits the amount of electricity that can flow through the cell, which makes it unable to produce adequate levels of chlorine necessary to keep the pool sanitized. I have a Saltron Reliant generator. This can happen for a few different reasons, such as: 1. We are not new to this and have never had our other pool do this. Push the reset button. #1 Have a Jandy aqua pure saltwater cell & i have a " no flow " reading is there a reset button that I have to hit inside the control box enclosed is a picture of the control box I cleaned the filter, added salt, backwashes, temp of water at 71 degrees installed new cell last year as well Attachments 00EC8870-88D5-4EE6-BFB0-12FB840EB179.jpeg But at some point down the road, eventually they will start acting up and require a bit of troubleshooting to determine if its the salt, the sensors, the cell, the board, the power supply. If the salt system is still within the warranty period, by all means, get on the phone with the manufacturers support reps for some advanced troubleshooting or warranty service. It is also possible that the chlorine in your pool is not working properly due to improper shock treatment. The Jandy AquaPure salt-water chlorine purifying systems use salt water to deliver high-performance water purification with uncompromised performance, reliability and hydraulic efficiency. This action maintains the cell. It is very pricey for the old style cell. All other forms of chlorine (tablets, powder, liquid, etc.) Check the water balance as usual. I havea Jandy APURE35. Good luck! First, check power. What does check cell mean on Jandy salt system? The salt under the effect of electrolysis, is transformed into sodium hypochlorite, a disinfectant. We constantly add algaeside and make sure the water is balanced but no luck. The Jandy TruClear Salt System, in my opinion, is a very reliable saltwater system but like everything you may see an error code on the screen. We see lots of infant mortality with the TruClear. Most cases of corrosion can be better explained by an incorrect water chemistry as opposed to the presence of salt. Salt cells are an integral part of saltwater pools, helping to sanitize the water and keep it safe for swimming. I have installed a new cell, could the motherboard be bad? Hi Davy If the salt level is too low, you can easily add more salt to the pool. In addition, chlorine levels can be stabilized easier with less dramatic fluctuations.While the salt water chlorinator prevents the user from needing to add chlorine to the pool on a regular basis, some maintenance, in regards to water balancing, will still need to be accomplished. Jandy AquaPure APURE1400 Manuals | ManualsLib Second, inspect your cell and make sure it is clean. i have sparks or tiny flames ciming from my c170 cell. The purer the salt, the better the life and performance of the electrolytic cell. (Use sodium chloride only). Avoid using salt with anti-caking agents (sodium ferrocyanide, also known as YPS or yellow prussiate of soda) that could cause some discoloration of fittings and surface finishes in pool.3. Video of the Day Step 2 Scroll to and highlight "System Setup" using the arrow keys. 2. It is 5 years old so not sure if it just died! This can usually be prevented by sealing the stone with a sealer.In the case of a salt water chlorinator, the salt may damage the stone along the water line over time (crystallization). Verified by strips and store. Sounds like something the manuf. Other units may have an indicator light to let you know when the cell needs to be manually cleaned. I would also check that salt level in the pool is 4000 ppm, +/- 200 ppm. The check cell light is on. Hi Lindsay, if the filter pressure is lower than normal, the pump impeller may be clogged. The GFCI should interrupt power. To begin, youll need to make sure the cell is disconnected from the power source. Jandy AquaPure 1400 Salinity Level | Trouble Free Pool In order to prevent salt cells from becoming damaged or malfunctioning, it is important to make sure that the cell is cleaned regularly, the metal probe is inspected for any signs of corrosion, and the electrical components are checked. Could be scale on the salt sensor, or bad connections maybe. Another way to tell if something is wrong with the salt cell is to check for calcium build-up or calcium scaling, which can limit the amount of chlorine the cell is able to produce. 8. I guess I would check the cable first, and end connections too, looking for crimping, or you could test for continuity, with the old adage, the problem lies where the power dies. Hi Fazel, sounds like Verify Cell, which may be appearing if you used a non-Jandy salt cell? The add salt light is on, and if i push the super chlorinate Button the light goes green. While the salt water chlorinator prevents the user from needing to add chlorine to the pool on a regular basis, some maintenance, in regards to water balancing, will still need to be accomplished. AquaPure service codes identify the problem and direct you to an available solution. Put the SWG system in 100% mod2.)e. The pilot was not registering anything wrong at the times I would go check, then finally the red lights on the sensor came on to indicate NO chlorine was generating. Troubleshooting Jandy AquaPure Error Codes inspect for any obvious signs of damage, anything melted or warped or burnt looking (look closely). Can you help. Every salt owner should have salt test strips. For a better experience, please enable JavaScript in your browser before proceeding. I am having an issue with the salt ppm reading when I go to the diagnostic mode and restart the generator the cell will run for 1 minute and turn off. Crazy glue perhaps? If no display at all, check the power cord, and outlet, be sure the Test button isnt popped, if its GFCI. 3000 parts per million of salt The maximum volume of water that can be treated with For swimming pools, a range of 1-3 ppm of free available . 2 out put fault (displayed for a second ). Troubleshooting a Salt Chlorinator. The conductivity is low due to the low water temperature which is how the salt level is measured. Heres the owners manual, or contact them here: I have an Autopilot salt system that is approx. 5. Be sure to get into all of the cracks and crevices with the hose, as dirt, debris and salt can build up in them over time. Corporate Aqua Products Blueriiot Grand Effects Jandy Polaris Zodiac Pool iAquaLink Blog Nature2 Cover-Pools. Tech set the chlorinator to 50% just to get it back on track.Took the water sample back still NO chlorine and they say the phosphate level is EXTREMELY HIGH. The display on the unit is showing as 3.9gpl and app shows the same 3900 PPM. The unit can make 1.25lb/24 hours at a recommended flow rate of 20-120GPM. The backup battery should be keeping the unit on, but should not be the cause of the unit turning off. I turn the power off for a few seconds and starts working fine again. Another common reason there is no chlorine in the pool is a lack of chlorine in the pool. So thats one possibility. Support Register Why a Jandy Pro Residential Catalog Commercial Catalog. It still bubbles but is using 17v but only using between 0.1a and 1.0a. Its been running (on high) for about 24 hours and I have zero chlorine in the pool I was hoping it was just faulty LEDs, but alas no. I would shock the pool with granular chlorine, (sometimes salt systems need an outside injection of chlorine to really shock the pool well) and see where that leads. If your filter is on the small side, it could need 18 hrs daily, especially during the heat of July. Dave JavaScript is disabled. The salt cell produces chlorine, but not salt that you have to add yourself. There is a Power Supply error message Output Fault that should display if that is the cause. if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[336,280],'remodelormove_com-narrow-sky-1','ezslot_23',168,'0','0'])};__ez_fad_position('div-gpt-ad-remodelormove_com-narrow-sky-1-0');In order to maintain healthy chlorine levels in your pool, you should perform regular maintenance, including filtering and chlorination. Hi, I have an Auto Pilot and it begins working fine but a few minutes (30 -40)it sends a warning that it has low volts. Flow sensors can also be mis-aligned with the water flow, or have scale deposits on the sensors, both of which can be corrected (on inground systems, not sure about the Intex system, which is more black box). Heres a video of a fellow with the same problem https://www.youtube.com/watch?v=jKruK1VlSH0 also clean the flow sensor electrode, which may have scale. My Jandy salt system is not making chlorine, 3-4 weeks, 3-4 Thanks again for your help! Cloudy water can also be from low chlorine production, but I would look at the filter first, and the amount of daily run-time, if you are in the habit of trying to run the pump as little as possible. This organic material can interact with the chlorine, breaking it down and consuming it. We have a Jandy AquaPure APURE35 that appears to have no power to it. Keep a pH level of 7.2-7.6 and your level of CYA (or stabilizer), at 30-50 ppm to reduce the workload on your salt cell. Create Your Own Saltwater Oasis Introducing the Jandy AquaPure Ei salt water sanitation system, a compact, self-contained solution. Look closely to inspect all wires, and connections, and look at the circuit board closely for any burnt marks or melted items. Knowing what the error code signifies is an. Any new postings here are unlikely to be seen or responded to by other members. Just make sure to clean pump strainer and filter to make sure the wat. I cleaned it but the light stays on. Shock treatment helps to balance the chemicals in your pool, but if not done properly, can have an adverse effect. The cell may also be bad too I dont have any experience with this problem, fortunately! Hi Joe, salt systems will be troublesome, at some point in their lives. Salt only needs to be added when necessary. Wouldnt it be simpler to just pour chlorine in the old way? When it rains it pours !! How do you dissassemble this? (liquid too, when used with a liquid pump). You may also need to recalibrate the salt level on the controller, if you have not tried that yet. Especially on my own pool! My user manual says to maintain salt level between 3.0 and 3.5gpl. Additionally, you should test your water regularly to ensure that the levels remain consistent and within the safe range. It may be that the chlorine has been used up due to heavy activity in the pool or it is not being added to the pool in the right amounts. Excessive moisture could also lead to a short inside the windings. Cleaning a Jandy pool salt cell is a fairly simple process. 45 subscribers Subscribe 47 21K views 7 years ago Reset procedure for Jandy Ei after replacing cell. If you still get flow errors, but you are sure that your flow rate is good, as good as its always been, then you can inspect the flow sensor, bypassing the switch to see if errors go away. My question is it a good idea to look for the cell only which is so far a pain or should i switch to new zodiac systems? Brush the pool bottom and allow water to circulate for 24 hours to dissolve salt completely and mix evenly Sorry for so many questions just not a simple answer, I suppose. Pentair makes a 60K gal salt system, in the IntelliChlor IC-60, if you need to switch to another large salt system. Take the cell out, thoroughly clean it, and re-install it. We cannot guarantee the life span of this surface in the long term. How To: Reset Average Salt 8 Step 3 Step 4 Step 1 The active salt readings ~instant salt appears in the Diagnostic Menu. Any new postings here are unlikely to be seen or responded to by other members. And of course it could be the circuit board. TruClear Saltwater Chlorinator | Jandy Cell is clean too. Reset procedure for Jandy Ei - YouTube It is used to purify and deodorize water, as well as to kill off any bacteria that may be present in it. Jandy AquaPure Electronic Salt Water Chlorinator And INSTALLATION AND OPERATION MANUAL PureLink Water Purification System Power Center and Cell Kit Models: APUREM PLC700 PLC1400 H0325600 Re F ENGLISH WARNING If these instructions are not followed exactly, a fire or explosion may result, causing property damage, personal injury, or death. Using salt test strips is recommended, even if your unit displays a digital salt level it could be wrong. My pool is about 55000 gals so it is rather large for a residential pool. It's a brand new pool. pH levels should always be tested before and after setting the salt cell percentage, as increased salt levels can raise the pH of your pool. You can always contact Zodiac, and ask for their recommendation. Easy ordering, timely delivery, great price and easy to install. To begin, you'll need to make sure the cell is disconnected from the power source. Can you trust the salt level reading? Wait for the relay to click (5 to 10 seconds). Had the same issue 5 years ago, and replaced sensor. have a circupool RJ30 plus salt system. my salt cell would not raise my ppm higher than 2600 no matter how long it runs. System Description 6 Electrical Speci Cations 7 Section 3. Chlorine is used to keep bacteria and other contaminants out of the pool and maintain the pH balance. I noted that the light on the display came on. Newer models self-clean and self-diagnose and have other advanced features. Your cell is under warranty. Now if that is all true, is the water temperature above 60 degrees, and is the salt level at recommended levels? My salt reading is not calibrated correctly Im showing 2000 and the pool store is reading in the 3000 range. For very hard water, some chlorinators can shorten the polarity inversion time (e.g. How do you calibrate a Jandy aquapure. The cell is recording The water is only 16C at the moment (its the start of the season here) but thats not been a problem in the past. The flow sensor or wire terminals may need cleaning, or it may need to be replaced, if flow (and filter pressure) is normal. Is there a way to calibrate the prologic system? Wait for the number to. Create a Saltwater Oasis in Your Backyard. How To Clean a Jandy TruClear Salt System - Chlorine King Pool ServiceIn this video I show you how to quickly and effectively clean a Jandy Tru Clear Salt Sy. You must log in or register to reply here. Hi, we have an Autochlor RP35T Chlorinator which is working when you turn it on or the timer turns it on and off as usual but there is no lights. Or a power cable failure, or it could just be a fuse, or a relay The problem lies where the power dies if you have a multimeter (and arent afraid to use it), you can troubleshoot where the incoming power is stopping. However, you may want to check with zodiac or another source, to be sure it would work. I have the Aqua Pure Ei system in for about 5-6 years. What would cause the transformer to go in my pool chlorinator that is what we have been told. Depending on the type of cell, repair may involve replacing parts, such as the electrodes and membrane, or cleaning out the cells, flushing out the plumbing, etc. Make sure the contacts are both in working order and securely attached. If still giving error message, replace the sensor good luck! The Jandy Troubleshooting Guide has two answers to the display "CHECK CELL", 1) Reason: Cell Overload.