The one I did find wanted $500! AquaPure service codes identify the problem and direct you to an available solution. I powered the system off and removed the cable to the cell. You must log in or register to reply here. The service code(s) are displayed twice per minute with an audible alarm" Your link has been automatically embedded. I have a Jandy Nature2 Fusion salt water system that is esentially an AquaPure 1400 system (I believe). You now have a manually chlorinated pool. To determine what is wrong for sure you need to trouble shoot the system by taking voltages at different test points. You need to take your readings with the cell connected and cell on (under load). http://www.jandy.com/html/productsupport/launchManual.php?url=H05675-RevE.pdf, http://www.pleasurepoolsno.com/manuals/ Manual.pdf, http://www.pleasurepoolsno.com/wp-conte Manual.pdf, Need help troubleshooting Jandy Aquapure 1400 SWCG, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Put the new cell in, and they were finally gone. For a better experience, please enable JavaScript in your browser before proceeding. Here are the details: 1) PIB board was replaced in October 2014 (about 1.75 years ago and problem really started about 6 months ago when PIB was 1.25 years old). 3) I measured the voltage at all of the test points and they are within spec, except the ones below: I put *** next to the Cell Connection Points readings because I was not able to figure out where the "test points" are on the PIB for the cell connection points, so I tested by shoving the probes into the top of the plugs that, in turn, are plugged into the PIB (so that the probes were touching the wire inside the plug). I will receive and install it tomorrow and report back. Jandy AquaPure Salt Water Pool Systems deliver high performance and reliable sanitation for swimming pools across the globe. Any new postings here are unlikely to be seen or responded to by other members. With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. AquaPure Troubleshooting AquaPure Control Center Flow/Temp/Salinity Sensor Cell Low Voltage Cable AquaPure Tee PureLink OR. Lets keep all the info in one topic. We are a registered 501(c)3 non-profit that is funded by user donations. Mine was 6 years old too. -25. Jandy AquaPure Error Codes / Installation and Operation Manual WARNING However, I read there should be 22-28 volts coming from the back board. 800-772-0467 This is there #. Same issues here on the 1400. So your resistance must be too high. Sign In Upload. I checked the voltage and it is 35V at the board and at the cell. Any help? So I turned off the unit (after reading that may be the issue), and turned it back on. Re: Aquapure SWG "general fault" code 120 can I still run fi. The new salt cell is much shorter/smaller than the old one. To keep these units running at top efficiency, the digital controls will display a code when something needs service. Started receiving service error code 120 on a five year old Aquapure cell. Started receiving service error code 120 on a five year old Aquapure cell. Typically you can expect to see about 5 years of life from the cell (10,000 hrs.). You will get much more visibility by. I installed the unit yesterday and it was fine - no service code. The service service light is not always on. There should be a pigtail off the control box to the unit that unplugs. Pasted as rich text. That is a very good price. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Verify the salinity level by other means than the controller. Hello , There was no answer in this thread for more than, Topics Merged. I have ordered a second Power Interface Board to see whether my cell voltage reading matches the workbook. I was not able to find a similar point on the "black & white" side, but it is difficult to move a probe around in there because space is tight. My cell didn't look bad either. Cleaned the cell, still got the codes. On the "green" side, there seems to be a little opening on the bottom left of the plug that also allows me to shove in the probe and get a reading (the same one I get when I shove the probe into the top of the plug). This seems odd to me since the cell is unplugged. That appears to be the concensus of the stuff I've read. Jandy 1400 171 And 190 Codes Won't Go Away Yes, 48 high it should normally be between 22-30 Volts DC. That makes everything you've done moot. Click here to shop our store. You are using an out of date browser. #2. Bama. Any new postings here are unlikely to be seen or responded to by other members. Chlorine is above 5 but still 120 persists. For a better experience, please enable JavaScript in your browser before proceeding. It may not display this or other websites correctly. Is there any way for a bad cell to be causing bad readings at the PIB? What is Jandy Aquapure error code 120? - Answers By So I turned off the unit (after reading that may be the issue), and turned it back on. Jandy AquaPure Electronic Salt Water Chlorinator And INSTALLATION AND OPERATION MANUAL PureLink Water Purification System Power Center and Cell Kit Models: APUREM PLC700 PLC1400 H0325600 Re F ENGLISH WARNING If these instructions are not followed exactly, a fire or explosion may result, causing property damage, personal injury, or death. Inground, Fiberglass and Aboveground Swimming Pools, Clearwater Spa Monaco 3 / nothing working except the circulation pump, 2015 Hot Springs Grandee - No Power Issue. Jandy Aquapure 1400 Salt Cell Cleaning and Error Codes May 26, 2012 Aquapure Service Codes Explained For those of you with a Jandy Aquapure Salt System, here's a helpful breakdown of what each service code means. You will need to take the cover off the control; box. If you have an account, sign in now to post with your account. Jandy AquaPure PLC1400 Error code 120 | Trouble Free Pool The cell was replaced 2 years ago, and the sensor was replaced one year ago. Everything reset - seemed fine. Or, since the readings at the PIB were also off, could the problem be originating with the PIB? Got the 171/190 codes so I replaced the backboard yesterday. (V = R * I) So your cell is probably bad. Jandy AquaPure PureLink 3-Port Salt Cell Kit | PLC1400 My system is 7 years old and I have only had to replace the sweep/cleaner & main pool pump and a few salinity sensors. I have power cycled the system a few times and the power was off when I installed the new PIB. You are using an out of date browser. Would the salinity sensor cause the 121 error code? The Power center is intermittently saying Service with error code 120. 120 code seems gone for now. Would the salinity sensor cause the 121 error code? However, there can be other reasons for low current as noted above. Getting service codes 125 & 194 on a Aqua Pure 1400. Or is it definitely the PIB? I would confirm this by placing an inductive amp meter on one of the cell wires. I have a 5 year old Jandy AquaPure 1400 cell that is throwing a 121 code. It is being practiced by thousands of pool owners just like you. 4-5 120 mVAC (with Cell On) Transformer CELL ON CELL RESTING FLOW CELL REVERSING ADD SALT SERVICE CHLORINE . 120 is low current. Jandy Aquapure Service Code 120 Issues | Trouble Free Pool Jandy Aquapure 1400 (rectangular style) 120 and 121 codes I have a Jandy Nature2 Fusion salt water system that is esentially an AquaPure 1400 system (I believe). I am having the same problem. Now it seems like it is happening every time we run it. Upload or insert images from URL. . Is this normal? We are a registered 501(c)3 non-profit that is funded by user donations. Thanks for the follow-up. Nevertheless, I pulled the DC cable from the cell and the center pin is loose and can almost be pulled right out. You didn't mention that you changed cell sizes. Hello , This is an inactive thread. I will try your suggestion when I get home this weekend and post the results. Re: Jandy Aquapure 1400 (rectangular style) 120 and 121 code. (Generates 173 - Low input voltage code if Level 2 code 188 is present) (Generates 170 code if 188 is not present) Contact a pool professional. Had a tech come out and was told that it was most likely a defective new sensor. Cleaned the cell, still got the codes. I installed the unit yesterday and it was fine - no service code. Jandy AquaPure Error Codes - INYOPools.com ePAPER READ DOWNLOAD ePAPER TAGS sensor salinity voltage indicates cycle chlorine input aquapure aqualink arrow jandy codes www.yumpu.com inyopools.com You also want an ePaper? 1 AquaPure 1400 Error Codes 172 181 My Aquapure 1400 (4th summer) has service codes 172,181. So 35 volts is an issue and may be solved by replacing the backboard? PDF INSTALLATION AND OPERATION MANUAL - United States | Jandy Had the same codes. . So whaddayathink, swap out the m601 backboard for the m301 and I should be good to go? Could you please give me specific directions on how to put an amp meter on one of the cell wires? I have visually checked the DC cord terminals. Any new postings here are unlikely to be seen or responded to by other members. Electronic salt water chlorinator and water purification system power center and cell kit (53 pages), Electronic salt water chlorinator, water purification system power center and cell kit (52 pages), Water purification system power center and cell kit (44 pages), Replacement kits for models apure35plg / 35plgc (4 pages), Optional surge suppression kit/pool and spa automation (8 pages), Aquapure ei series I also have cleaned the cell. Stupid question, but what do you mean by "cell wire"? It doesn't appear to be generating chlorine, so I have been chlorinating the pool with liquid chlorine. No chlorine is being produced. Upon getting some service codes I cleaned the cell, and went through all the checks posted on this site to check out the board and sensor. What does my Jandy AquaPure faults code mean and like can I resolve it? That's normal as far as the plus and minus. Skip to contents. What does that show? 2 . I am dreading the replacement of the system because that would mean re-plumbing the system. I also noticed that after replacing my older Jandy 1400 model with the updated one that the salt sensor was WAY more sensitive than the model I replaced. Chloromatic Code 120 121 By Transplants June 20, 2010 in All Swimming Pools Types Share Reply to this topic Start new topic Transplants Members 5 Posted June 20, 2010 I have a chloromatic III cm601 that has the codes 120 or 121 depending on when I look. I cleaned the cell recently and measured the voltage with the cable off of 11.4 volts. You would just clamp the meter on to the wire you want to measure and it measures amp draw through the wire. For a better experience, please enable JavaScript in your browser before proceeding. dual voltage 240v/120v (36 pages), Watercolors led lights underwater large and small light (16 pages), Watercolors led, underwater large and small light (20 pages), Bubbler with pressure check technology (36 pages), Pro series. Jandy AguaPure Code 124 - INYO Pools Forum It is working well, it has only been installed for a week. Clear editor. The cell is clean. Jandy AquaPure 1400 121 Error Code | Trouble Free Pool You should get about 7 amps out of it. PIB power supply either too low or too high (Low input voltage code 173 if Level II code 188 is present) (code 170 if 188 is not present). That makes everything you've done moot. You cannot paste images directly. It is throwing a low salt code with salt at 2400 but I don't believe that is related to the code 120. Troubleshooting Jandy AquaPure Error Codes - The Pool Life June 20, 2010 in All Swimming Pools Types. Started receiving 121 and 120 service codes. Each time quite a bit of scale fell from the cell and there was fairly vigorous bubbling. Your link has been automatically embedded. I got 8.6. note: my probes were too thick to reach the green and black plates. You are using an out of date browser. The temp is good, the flow is on, and the salinity looks good as well. What is Jandy Aquapure error code 120? JavaScript is disabled. I followed the instructions in the manual just to be safe. spozz I purchased mine from "POOL SupplyWorld" on the web- Jandy Aquapure PLC700 PureLink 7-Blade Cell Kit - Up To 15,000 Gallons. Sure, I replaced my old chlorinator cell with the new jandy. If the cell is over 5 years (10,000 hrs. Front board power supply either too low or too high. However, I read there should be 22-28 volts coming from the back board. JANDY. The 120 code is back. If I remove the power cable and put it back on the cell it disappears for a bit. Any new postings here are unlikely to be seen or responded to by other members. It may not display this or other websites correctly. We are a registered 501(c)3 non-profit that is funded by user donations. Clear editor. Utilize the chart below to help identify the error code, the possible cause, and corrective action. 189. Anyone else had to live with tabs in the skimmer? It is being practiced by thousands of pool owners just like you. If you mean normal and reversing, I'll check it. PDF AquaPure Troubleshooting - INYOPools.com If you have an account, sign in now to post with your account. Pool is only 8,000 gallons so typically runs at 30-40% for 10 hours/day year-around. cs filters (48 pages), Jandy pro series electronic water leveler (4 pages), Manual will be automatically added to "My Manuals", Original Aquapure, Purelink, and Cm3 Test Points- - Back Board Transformer and Cell Voltage Tests, Water Filtration Systems Jandy AquaPure Installation And Operation Manual, Water Filtration Systems Jandy PureLink Installation And Operation Manual, Lighting Equipment Jandy AquaPure Ei Series Manual, Lighting Equipment Jandy AquaPure Ei Series Instructions, Lighting Equipment Jandy AquaLink RS Installation Manual, Lighting Equipment Jandy AquaLink TCX Installation And Operation Manual, Lighting Equipment Jandy APURE35 Installation And Operation Manual, Lighting Equipment Jandy Pro Series Installation Manual, Lighting Equipment Jandy WaterColors LED Installation Manual, Lighting Equipment Jandy TruFit JHCBUB Owner's Manual, Lighting Equipment Jandy CS100 Installation And Operation Manual, Lighting Equipment Jandy TruFit Bubbler Owner's Manual, Lighting Equipment Jandy Laminar Jet Installation And Operation Manual, Lighting Equipment Jandy iAquaLink 3.0 Quick Start Manual, Lighting Equipment Jandy Levolor K-1100 Installation Instructions, Page 17: Troubleshooting - Transformer Voltage, Page 19: Power Interface Board (Pib) Dc Voltage, Page 29: Original Aquapure, Purelink, And Cm3 Test Points- - Back Board Transformer And Cell Voltage Tests. I have the APUREM power center and the jandy salt cell. You must log in or register to reply here. Called to verify stock before purchase and the staff was courteous and knowledgeable. The first 2 numbers of the serial number are the year it was made. Increase the reach of your titles YUMPU automatically turns print PDFs into web optimized ePapers that Google loves. Here's a link to the troubleshooting guide I have used: I know it is now 2016 but I have the same problem. Does this indicate it's getting old and needs replacing? Troubleshooting Jandy AquaPure Error Codes - Leslie's Pool Supplies Great resource. 188. Note: Your post will require moderator approval before it will be visible. Tried acidwash, but still didn't solve the problem (the DC cord looked fine). Should I take the salinity sensor out and clean it with a scotchbrite pad? Getting service codes 125 & 194 on a Aqua Pure 1400. - JustAnswer Please Help! I have apure700 chlorine generator is showing a 120 code, . PDF Installation and Operation Manual Now this morning, the 121's gone but it's back to the 120 code After testing the back board and cell, I found there to be 35 volts. I would imagine it's at least 5 years old, I moved in to this house 3 years ago. I am receiving the same error codes on our Jandy Salt System (121). To determine what is wrong for sure you need to trouble shoot the system by taking voltages at different test points. Wiki User 2011-12-16 23:38:47 Study now See answer (1) Best. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. If I remove the power cable and put it back on the cell it disappears for a bit. Upon getting some service codes I cleaned the cell, and went through all the checks posted on this site to check out the board and sensor. TIA!!! It's been tossing out error code 120/121 for low flow. So I figured I would bite the bullet and purchased a new PLC700 kit with new cell, DC cable, and sensor. I have the Jandy APUREM Power Center and the 3-port PLC1400 cylindrical salt cell. I cleaned the cell recently and measured the voltage with the cable off of 11.4 volts. Getting service codes 125 & 194 on a Aqua Pure 1400. I have checked the chlorine level and the cell is definately making chlorine but the level is lower than it should be being at 100%. Transfer and labor is near $500 and New system is $1500 plus labor. Pool Clown helped me before so I am looking for help again. The first time it happened, I cleaned the cell and it seemed to settle down for a couple of days. You can post now and register later. Please edit your content to remove the highlighted words below. LEVEL 2 SERVICE CODES May 1, 2012. Good morning. Thanks for the follow-up. I am receiving the same error codes on our Jandy Salt System (121). When you say control module, what are you referring to exactly? Considering the age of the cell it's highly probable that it needs to be replaced. 53073 Jandy AquaPure PureLink 3-Port 14-Blade Replacement Salt Cell Kit | 40,000 Gallons | PLC1400. #9. What causes error codes 1400, 172, and 180 on an Aquapure? - JustAnswer The SERVICE indicator is accompanied by a service code displayed on the front panel, displayed as a 3 digit code. You are using an out of date browser. Sounds like a problem with the reversing relay in the unit. I replaced the PIB (Power Interface Board) and the error code is still present. Is that the test point? Is Hayward TURBO CELL (T-CELL-15-SWP - Self Cleaning? You will get much more visibility by, Topics Merged. All the relay does is reverse the polarity of the voltage to the cell plates. Sounds like a problem with the reversing relay in the unit. Need help troubleshooting Jandy Aquapure 1400 SWCG, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. AP700 and AP1400 Exploded Views . Based on the manufacturing date, It seems to have reached the end of its life. test 2 for 120mVDC: the expected value was 100 to 145. If we need a new cell, any recommendations. I pulled the salt cell (square) and it is clean as a whistle.however, I still cleaned it with 50/50 muriatic acid water mix. I went through the whole process, very similar to what was posted earlier, but with pictures and flow charts. AquaPure lighting equipment pdf manual download. Unfortunately, your content contains terms that we do not allow. 35.6 volts in both directions when connected to the cell. I _think_ its the cell, it's about 6 years old. Cleaned sensors with scrubbie pad and tested board with 1 number different than what they should be. There are three wires to the cell in there, Clamp the green one. PoolSpaForum.com Make sure you read blakej's first response in this thread as he lists the problems that there could be with a 121 error code. It seems as if the hot water may have fixed the error code or something. 6 yrs old. My chlorine actually shut down and the pool started to turn green. I noticed that the power supply on the Jandy Aquapure for the cholorinator never seemed to come on. Display as a link instead, I was under the impression that the bakboard produces the voltage and the cell operates at between 22 and 28 volts. Jandy Aquapure 1400 Error 120 | Trouble Free Pool Questions? The wire going from the PCB to the cell? 1 4 comments Best Add a Comment DoughBoy_65 9 mo. The unit appears to work for a little less than an hour and then posts either service code 120 or 121. Good morning. I cleaned it and everything. I tried. That can be from low salt, low water temperature, a bad power cord, cell plates corroded or loose power pins. We are a registered 501(c)3 non-profit that is funded by user donations. You didn't mention that you changed cell sizes. My AquaPure is reading Lo (low temperature), but the water We removed and inspected the cell, it seems fine. VAC input voltage is too low. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. To troubleshoot any code, set the production to 100% and follow the steps below for that code. Did you replace the flow sensor with the salt cell? I'd hate to replace the cell for $700 and then that not be the problem. How do we test it at the cell with the 3 posts. Is it a sensor or board. Lets keep all the info in one topic. Please consider. Jandy General Fault - All Swimming Pools Types - Pool and Spa Forum
Georgia Superintendent Of The Year 2023, Articles J